857 research outputs found
Charting service quality gaps
Some of the most influential models in the service management literature (Parasuraman et al., 1985; Grönroos, 1990) focus on the concept of service quality gap (SQG). Parasuraman et al. (1985) define a pioneering model with five SQGs, the concepts of which are amplified in Brogowicz et al.âs (1990) model. The latter has five types of encompassing gaps: information and feedback-related gaps; design-related gaps; implementation-related gaps; communication-related gaps; and customersâ perceptions and expectations related gaps. Additionally to this model amplification, other authors (e.g., Brown & Swartz, 1989) have pointed to relevant SQGs that have not been considered previously.
This paper integrates current models and a group of SQGs dispersed through the literature in a new comprehensive model. It draws a link between the model and the stages of a strategy process, emphasising the SQGsâ impact on the process and raising relevant research questions.FCT, FEUALG, UALG
Measuring Metacognition in Cancer: Validation of the Metacognitions Questionnaire 30 (MCQ-30)
Objective
The Metacognitions Questionnaire 30 assesses metacognitive beliefs and processes which are central to the metacognitive model of emotional disorder. As recent studies have begun to explore the utility of this model for understanding emotional distress after cancer diagnosis, it is important also to assess the validity of the Metacognitions Questionnaire 30 for use in cancer populations.
Methods
229 patients with primary breast or prostate cancer completed the Metacognitions Questionnaire 30 and the Hospital Anxiety and Depression Scale pre-treatment and again 12 months later. The structure and validity of the Metacognitions Questionnaire 30 were assessed using factor analyses and structural equation modelling.
Results
Confirmatory and exploratory factor analyses provided evidence supporting the validity of the previously published 5-factor structure of the Metacognitions Questionnaire 30. Specifically, both pre-treatment and 12 months later, this solution provided the best fit to the data and all items loaded on their expected factors. Structural equation modelling indicated that two dimensions of metacognition (positive and negative beliefs about worry) were significantly associated with anxiety and depression as predicted, providing further evidence of validity.
Conclusions
These findings provide initial evidence that the Metacognitions Questionnaire 30 is a valid measure for use in cancer populations
Recommended from our members
Environmental Measurement While Drilling System for Real-Time Field Screening of Contaminants
Sampling during environmental drilling is essential to fully characterize the spatial distribution and migration of subsurface contaminants. However, analysis of the samples is expensive and time-consuming: off-site laboratory analysis can take weeks or months. Real-time information on environmental conditions, drill bit location and temperature during drilling is valuable in many environmental restoration operations. This type of information can be used to provide field screening data and improved efficiency of site characterization activities. The Environmental Measurement-While-Drilling (EMWD) System represents an innovative blending of new and existing technology in order to obtain real-time data during drilling. The system consists of two subsystems. The down-hole subsystem (at the drill bit) consists of sensors, a power supply, a signal conditioning and transmitter board, and a radio-frequency (RF) coaxial cable. The up-hole subsystem consists of a battery pack/coil, pickup coil, receiver, and personal computer. The system is compatible with fluid miser drill pipe, a directional drilling technique that uses minimal drilling fluids and generates little to no secondary waste. In EMWD, downhole sensors are located behind the drill bit and linked by a high-speed data transmission system to a computer at the surface. Sandia-developed Windows{trademark}-based software is used for data display and storage. As drilling is conducted, data is collected on the nature and extent of contamination, enabling on-the-spot decisions regarding drilling and sampling strategies. Initially, the downhole sensor consisted of a simple gamma radiation detector, a Geiger-Mueller tube (GMT). The design includes data assurance techniques to increase safety by reducing the probability of giving a safe indication when an unsafe condition exists. The EMWD system has been improved by the integration of a Gamma Ray Spectrometer (GRS) in place of the GMT. The GRS consists of a sodium iodide-thallium activated crystal coupled to a photomultiplier tube (PMT). The output of the PMT goes to a multichannel analyzer (MCA).The MCA data is transmitted to the surface via a signal conditioning and transmitter board similar to that used with the GMT. The EMWD system is described and the results of the GRS field tests and field demonstration are presented
Recommended from our members
Environmental measurement-while-drilling-gamma ray spectrometer (EMWD-GRS) system technology demonstration plan for use at the Savannah River Site F-Area Retention Basin
The Environmental Measurement-While-Drilling-Gamma Ray Spectrometer (EMWD-GRS) system represents an innovative blend of new and existing technology that provides the capability of producing real-time environmental and drillbit data during drilling operations. This demonstration plan presents information on the EMWD-GRS technology, demonstration design, Cs-137 contamination at the Savannah River Site F-Area Retention Basin, responsibilities of demonstration participants, and the policies and procedures for the demonstration to be conducted at the Savannah River Site F-Area Retention Basin. The EMWD-GRS technology demonstration will consist of continuously monitoring for gamma-radiation contamination while drilling two horizontal boreholes below the backfilled retention basin. These boreholes will pass near previously sampled vertical borehole locations where concentrations of contaminant levels are known. Contaminant levels continuously recorded by the EMWD-GRS system during drilling will be compared to contaminant levels previously determined through quantitative laboratory analysis of soil samples
A Survey on Retrieval of Mathematical Knowledge
We present a short survey of the literature on indexing and retrieval of
mathematical knowledge, with pointers to 72 papers and tentative taxonomies of
both retrieval problems and recurring techniques.Comment: CICM 2015, 20 page
Adaptive response and enlargement of dynamic range
Many membrane channels and receptors exhibit adaptive, or desensitized,
response to a strong sustained input stimulus, often supported by protein
activity-dependent inactivation. Adaptive response is thought to be related to
various cellular functions such as homeostasis and enlargement of dynamic range
by background compensation. Here we study the quantitative relation between
adaptive response and background compensation within a modeling framework. We
show that any particular type of adaptive response is neither sufficient nor
necessary for adaptive enlargement of dynamic range. In particular a precise
adaptive response, where system activity is maintained at a constant level at
steady state, does not ensure a large dynamic range neither in input signal nor
in system output. A general mechanism for input dynamic range enlargement can
come about from the activity-dependent modulation of protein responsiveness by
multiple biochemical modification, regardless of the type of adaptive response
it induces. Therefore hierarchical biochemical processes such as methylation
and phosphorylation are natural candidates to induce this property in signaling
systems.Comment: Corrected typos, minor text revision
Energy loss of proton and lead beams in the CERN-SPS
The energy loss of an unbunched beam circulating in the CERN-SPS has been obtained from the observed frequency change of a longitudinal Schottky signal. This experiment was carried out for protons at 14, 120 and 270 GeV/c and for lead ions PB82208 at Z .270 GeV/c momentum. The dominant effects which determine the energy loss are synchrotron radiation, ionization of the residual gas and parasitic mode loss in the resistive longitudinal impedance. Since all the protons in a lead nucleus radiate coherently the synchrotron radiation is proportional to Z2 like the other effects. The experimental results are analyzed and the contributions of the individual effects determined. Using an impedance of | Z/n | ~ 12 W gives the best fit through the experimental data
Recommended from our members
Integration and Evaluation of a Position Sensor with Continuous Read-Out for use with the Environmental Measurement-While-Drilling Gamma Ray Spectrometer System
The Environmental Measurement-While-Drilling-Gamma Ray Spectrometer (EMWD-GRS) system represents an innovative blend of new and existing technology that provides real-time environmental and drill bit data during drilling operations. The EMWD-GRS technology was demonstrated at Savannah River Site (SRS) F-Area Retention Basin. The EMWD-GRS technology demonstration consisted of continuously monitoring for gamma-radiation-producing contamination while drilling two horizontal boreholes below the backfilled waste retention basin. These boreholes passed near previously sampled locations where concentrations of contaminant levels of cesium had been measured. Contaminant levels continuously recorded by the EMWD-GRS system during drilling were compared to contaminant levels previously determined through quantitative laboratory analysis of soil samples. The demonstration of the EMWD-GRS was a complete success. The results show general agreement between the soil sampling and EMWD-GRS techniques for CS-137. It was recognized that the EMWD-GRS tool would better satisfy our customers' needs if the instrument location could be continuously monitored. During the demonstration at SRS, an electromagnetic beacon with a walkover monitor (Subsite{reg_sign}) was used to measure bit location at depth. To use a beacon locator drilling must be stopped, thus it is normally only used when a new section of pipe was added. The location of contamination could only be estimated based on the position of the EMED-GRS package and the distance between locator beacon readings. A continuous location system that would allow us to know the location of each spectrum as it is obtained is needed
Acceleration of High Intensity Proton Beams
In 1998 the CERN SPS accelerator finished a five years long program providing 450GeV proton beams for neutrino physics. These experiments required the highest possible beam intensity the SPS can deliver. During the last five years the maximum proton intensity in the SPS has steadily been increased to a maximum of 4.8 1013 protons per cycle. In order to achieve these intensities a careful monitoring and improvement of the vertical aperture was necessary. Improved feedback systems on the different RF cavities were needed in order to avoid instabilities. Also the quality (emittance and extraction spill) of the injector, the CERN PS, had be optimised
The SPS as lead-ion accelerator
In 1995 the CERN SPS was used during two months to accelerate fully stripped ions of the Pb208 isotope from the equivalent proton momentum of 13 GeV/c to 400 GeV/c. The radio frequency swing which is needed in order to keep the synchronism during acceleration is too big to have the SPS cavities deliver enough voltage for all frequencies. In a first stage, the beam is accelerated from 13 GeV/c to 26 GeV/c using the fixed frequency mode. During this stage the beam is grouped in four 2msec batches, separated by 3msec holes during which the frequency is changed in order to keep synchronism. At 26 GeV the beams are de-bunched and recaptured in order to fill the 3msec holes. From there on the lead ions are then accelerated up to 400 GeV/c with the normal frequency program. The de-bunching and recapture at 26 GeV improved the effective spill at extraction by a factor of three. Intensities up to 3.9 1010 charges could be obtained at 400 GeV/c. The total efficiency of the two RF captures was 64%
- âŠ